Reference number
ISO 11127-2:1993
ISO 11127-2:1993
Preparation of steel substrates before application of paints and related products — Test methods for non-metallic blast-cleaning abrasives — Part 2: Determination of particle size distribution
Edition 1
1993-12
Withdrawn
ISO 11127-2:1993
19138
Withdrawn (Edition 1, 1993)

Abstract

The procedure includes weighing out a test portion of approximately 300 g of the sample, placing the test portion in the top sieve of a set of test sieves (including all the sieves listed against the grade under test in the appropriate part of ISO 11126) with the largest-aperture sieve on the top and progress to the smallest aperture at the bottom with a pan, to catch any abrasive that falls through the finest sieve, sieving in a sieve machine, weighing the abrasive retained on each sieve and transferred on to a balance pan. Annex A gives information on the international standards series for non-metallic blast-cleaning abrasives ISO 11126 and ISO 11127.

General information

  •  : Withdrawn
     : 1993-12
    : Withdrawal of International Standard [95.99]
  •  : 1
     : 3
  • ISO/TC 35/SC 12
    25.220.10 
  • RSS updates

Got a question?

Check out our Help and Support